projects:diytig:menu:pulseweld

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
projects:diytig:menu:pulseweld [2022/08/14 21:37] spsmithprojects:diytig:menu:pulseweld [2022/09/30 22:59] (current) spsmith
Line 5: Line 5:
 - **Pulse Rate**  - **Pulse Rate** 
   * 1 - 50 per second   * 1 - 50 per second
-How many peak amp pulses will be generated per second.+How many peak amp pulses will be generated per second.\\ 
 +Step size: 1 Second
  
 ---- ----
Line 11: Line 12:
 - **Background Amps** - **Background Amps**
   * 10 - 200 Amps (limited by 'Max Amps' value)   * 10 - 200 Amps (limited by 'Max Amps' value)
-This is the current level that will be maintained in between the peak amp pulses.+This is the current level that will be maintained in between the peak amp pulses.\\ 
 +Step size: 1 Amp
  
  
Line 20: Line 22:
 This value determines how much time will the peak amp pulse will be 'on' versus 'off'. \\ This value determines how much time will the peak amp pulse will be 'on' versus 'off'. \\
 T(total) = T(on) + T(off) \\ T(total) = T(on) + T(off) \\
-T(total) would be repeated within each second as determined by //Pulse Rate//+T(total) would be repeated within each second as determined by //Pulse Rate//\\ 
 +Step size: 1%
  
  
Line 26: Line 29:
  
 - **Peak Pulse Amps** - **Peak Pulse Amps**
-  * A value between //Background Amps// and //Max Amps// variables.+  * A value between //Background Amps// and //Max Amps// variables.\\ 
 +Step size: 1 Amp
  
  
 ---- ----
 [[projects:diytig:menu|BACK]] [[projects:diytig:menu|BACK]]
  • projects/diytig/menu/pulseweld.txt
  • Last modified: 2022/09/30 22:59
  • by spsmith