projects:diytig:menu:amps

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
projects:diytig:menu:amps [2022/09/30 22:50] spsmithprojects:diytig:menu:amps [2022/09/30 22:51] (current) spsmith
Line 8: Line 8:
      * 10 - 200 Amps      * 10 - 200 Amps
      Max Amps describes the maximum current that can be achieved through the full motion of the foot pedal. Full forward travel of the pedal would denote the maximum value.\\      Max Amps describes the maximum current that can be achieved through the full motion of the foot pedal. Full forward travel of the pedal would denote the maximum value.\\
-Step size: 1Amp+Step size: 1 Amp
            
  
Line 17: Line 17:
      * 10 - 200 Amps      * 10 - 200 Amps
      Start amps is the current that will flow at the initiation of the arc, whether in conjunction with the HV/HF starter or not. A high value will help here, but will also cause significantly more heat to be introduced to the material being welded. The lowest value possible is always best. This will vary with differing scenarios.\\      Start amps is the current that will flow at the initiation of the arc, whether in conjunction with the HV/HF starter or not. A high value will help here, but will also cause significantly more heat to be introduced to the material being welded. The lowest value possible is always best. This will vary with differing scenarios.\\
-Step size: 1Amp+Step size: 1 Amp
  
  
Line 25: Line 25:
    * **Up Slope**    * **Up Slope**
      * Amps/Second      * Amps/Second
-     Up Slope determines how quickly the current will be raised from zero to Start Amps after the foot switch is closed. Setting this to '0' will disable this function. +     Up Slope determines how quickly the current will be raised from zero to Start Amps after the foot switch is closed. Setting this to '0' will disable this function.\\ 
 +Step size: 1 Amp
  
 ---- ----
Line 33: Line 33:
    * **Down Slope**    * **Down Slope**
      * Amps/Second      * Amps/Second
-     Down Slope determines how quickly the current will be reduced from Start Amps to zero after the foot switch is opened. Setting this to '0' will disable this function. +     Down Slope determines how quickly the current will be reduced from Start Amps to zero after the foot switch is opened. Setting this to '0' will disable this function.\\ 
 +Step size: 1 Amp
  
 ---- ----
Line 41: Line 41:
    * **End Amps**    * **End Amps**
      * 10 - 200 Amps      * 10 - 200 Amps
-     End Amps determines what current level should be maintained during the end of the weld. The welder can choose to snap out the electrode to end the weld once finished, or simply set this value to '0 to disable the function.+     End Amps determines what current level should be maintained during the end of the weld. The welder can choose to snap out the electrode to end the weld once finished, or simply set this value to '0 to disable the function.\\ 
 +Step size: 1 Amp
            
  
  • projects/diytig/menu/amps.1664542238.txt.gz
  • Last modified: 2022/09/30 22:50